Plasmonic detectors enable quantum-level terahertz detection sensitivity at room temperature

A newly developed plasmonic detector enables quantum-level sensitivity at room temperature, for the first time. This could enable various planetary, cosmological, and astrophysical observations to be made without the need for cryogenic cooling.

Radiation in the terahertz regime exhibits warm phenomena, such as formation of stars, planetary systems, and galaxy evolution as well as dynamics and atmospheric constituents of planets and comets. Formation of stars and planetary systems and various important phases of galaxy evolution happen in dust cloud regions, which obscure infrared and optical wavelengths. On the other hand, temperature range of the interstellar medium in these regions excites a wealth of spectral lines in the terahertz regime, which are not blocked by the interstellar dust. Many of these spectral lines have been investigated through several ongoing and completed observatory missions to study the evolution of galaxies, stars and planets; dynamics of interstellar medium of nearby galaxies; evolution of solar system and proto-planets; and cosmic origin of water on Earth and other planets.

Many of these observations require terahertz spectrometers with near-quantum-limited sensitivities to detect faint fluxes of terahertz photons emitted from galaxies that are thousands of light-years away. Such sensitivities have so far only been possible through the use of cryogenically cooled spectrometers kept close to absolute zero (-273 C˚) to work properly. Although cryogenic-cooling does not pose a substantial limitation to the ground-based instruments, it significantly constraints the lifetime and weight of the instruments carried by satellites. For example, the billion-euro Herschel observatory launched for terahertz observations, carried 2367 liters of liquid helium in a giant cryostat for cooling the terahertz spectrometers. The carried liquid helium weighed 335 kg, while the weight of the rest of the instruments was 426 kg. The lifetime of this observatory was limited to a total 22,000 hours of scientific observations, after which the liquid helium totally boiled away.

In a new paper published in Nature Astronomy, we introduce a plasmonic detector capable of detecting faint terahertz spectral lines with quantum-level sensitivities at room temperature, for the first time. The key to the new detector is converting incoming terahertz signals, which are not easy to sense and analyze with standard scientific equipment, into radio waves that are easy to handle. For this conversion, we mix the incoming terahertz signal with light in a semiconductor with embedded metallic nanostructures that are designed to enhance the interaction between the light and terahertz photons. We demonstrate terahertz detection sensitivities down to 3 times the quantum-limit at room temperature. With a versatile design capable of broadband operation, over a 0.1-5 THz bandwidth, this plasmonic detector has broad applicability to astronomy, cosmology, and atmospheric studies, as well as gas sensing.

Source: https://astronomycommunity.nature.com/

Related presentations

Login to access our presentations

Liked this post?

Share it on your social networks